S-Series: Sensor Based

LC8 Controller

SINGLE LEVEL
Lighting Controller

The LC8 lighting controller automatically switches a dry contact in response to changes in natural daylight. The LC8 provides a maintained single pole, double throw “form C” relay output to drive electrically held contactors or relays, or inputs to Energy Management Systems (EMS). The LC8 can control incandescent, fl uorescent or HID lighting. The low voltage controller requires a remotely
mounted CES sensor.

 

The dual setpoint LC8 precisely switches loads according to the selected light level confi guration. LOW and HIGH light levels are calibrated to their setpoints at the control board. As the sensor detects a diminishing light level that corresponds with the LOW setpoint, the control board matches the two signals and the lights are switched ON. As the sensor detects an increased light level, the control board’s HIGH setpoint switches the lights OFF. The LOW and HIGH setpoints are separated by a “deadband”. This prevents the sensor from switching light levels between the setpoints, thus eliminating nuisance
or intermittent changes.


For direct switching capability of 120 VAC and 277 VAC circuits, PLC-MULTIPOINT UL listed PCS/120 or PCS/277 may be used. All products are factory tested to assure maximum reliability. The advantages of using the LC8 lighting control system are found in stability, versatility, quality and accuracy. The LC8 offers
precision light measurement setpoints that are stable once set and the fl exibility to be applied to many
different lighting environments.

 

 

 

 

LC81, LC82 System

SINGLE & DUAL LEVEL
Lighting Control System

The LC81, LC82 photo sensor lighting control systems automatically switch dry contacts in response to changes in natural daylight. The LC81, LC82 controllers are available in a Basic(B) model as well as a
Standard(S) model.

 

The LC81-B, LC82-B systems include one or two LC8 control boards, internal Hand/Off/Auto Switch per LC8, terminal blocks and one or two 20A switching relays housed in a NEMA 1 hinged door enclosure. The systems include one CES sensor.

 

The LC81-S, LC82-S is expanded to include an on-door illuminated HOA switch, fused input power, and room for other options such as a 24hr time-clock or additional 20A power circuits housed in a larger

NEMA 1 enclosure. The LC8 based systems are capable of switching control of incandescent, fluorescent and HID lighting loads. An optional 1/2 hour “Hold On” timer may be ordered to prevent the short cycling of HID lamps. The dual setpoint system precisely switches loads according to the selected light level confi guration. LOW and HIGH light levels are calibrated to their setpoints at the control board. As the sensor detects a diminishing light level that corresponds with the LOW setpoint, the control board matches the two signals and the lights are switched ON. As the sensor detects an increasing light level, the control board’s
HIGH setpoint switches the lights OFF. The LOW and HIGH setpoint separation creates a “deadband”.

 

This prevents the sensor from switching light levels between the setpoints, thus eliminating nuisance or intermittent changes.To assure optimum performance and highest standards, all electronic components
are of computer grade quality and assembled onto a fi berglass epoxy circuit board. All components are factory tested to assure maximum reliability. The entire assembly is mounted in a NEMA 1 hinged door
enclosure with the high and low voltage components separated by a barrier. The Basic size is used with limited outputs and options. The larger Standard size is used when the application requires more
options or additional circuits. The system is constructed to UL508A standards and each unit carries an Electrical Testing Laboratories label. The advantages of using the LC81, LC82 lighting control system are
found in stability, versatility, quality and accuracy. The LC81, LC82 offers a complete, stand-alone system package. Once mounted, the sensor, power and lighting loads need only to be wired, and the
system is ready to operate.

 

 

 

 

LC81/LC82

LC3X Controller

THREE LEVEL
Lighting Controller

The LC3X automatically switches three dry contacts in response to changes in natural daylight, utilizing
independent setpoints. The LC3X controller requires a separate PD style sensor and optional 3X/PD adapter to complete the low voltage system. The LC3X can be configured as a stand-alone controller, or for cascaded operation, with a master LC3X providing the sensor signals to slave controllers.

 

Options include the 3X/PD Photodiode adapter; which provides the sensor’s gain calibration, the 3X/T Timer which has multiple time ranges and selection of interval or additive functions, and the PD Simulator which is used to verify voltages of footcandle levels.

 

 

Downloads

Brochure -

Data Sheets - LC8 pdf; LC81,LC82 pdf; LC3X pdf

Application Notes -

Specifications - PDF

Engineering Drawings - DWG

Installation and Maintenance Manual - LC8 pdf; LC8 T455 pdf

 

 

 